  mar. 2002 outline drawing mitsubishi hybrid ic M57147AU-01 ipm power supply unit block diagram description the M57147AU-01 is an insulated dc-dc converter de- signed to drive the ipm. 6 outputs can obtain from an input of 140 ~ 380vdc. the terminals between inputs and outputs, and each outputs are insulated. features  input ................................................... 140 ~ 380vdc  output ................................................ +15v, 50max3 +15v, 150max1 +12v, 400max1 +5v, 300max1  electrical isolation (between input and outputs) ........................................................... 1500vrms 1minute  electrical isolation (between each outputs) ........................................................... 1500vrms 1minute application power supply for ipm drive dimensions: mm 18 1 19 36 M57147AU-01 xxxx lot no pin no 82max 50 0.7 80.35 0.35 0.2 2.54 0.55 0.1 2.54 ? 17=43 33 max 1.6 4.5 1.5 (3.41) control circuit vo1+ vo2+ vo3+ vo4+ 18 vo6+ vo5+ vin+ vin 17 16 12 11 10 vo5,6 vo4 vo3 vo2 vo1 19 20 24 25 29 30 35 1 2 3 5 4 34
mar. 2002 mitsubishi hybrid ic M57147AU-01 ipm power supply unit maximum ratings (ta = 25 c, unless otherwise noted) v v v v ma c c w vrms vrms 380 50 150 400 300 10 ~ 70 20 ~ 85 *10.8 1500 1500 ratings symbol parameter conditions unit 140 14 14 14 14 11 4.75 15 15 15 15 12 5.0 0.3 0.3 0.3 0.3 0.2 0.1 380 16 16 16 16 14 5.25 0.5 0.5 0.5 0.5 0.5 0.2 symbol unit parameter test conditions limits min. typ. max. input voltage output current operating temperature storage temperature total output power electrical isolation between input and outputs electrical isolation between each outputs vin i l t opr t stg po viso1 viso2 vo1, vo2, vo3 vo4 vo5 vo6 no condensation no condensation sine wave voltage, 60hz, 1 minutes sine wave voltage, 60hz, 1 minutes recommended range io1 = 5 ~ 50ma, io2 = io3 = 5ma, io4 = 25ma io5 = 200ma, io6 = 200ma io2 = 5 ~ 50ma, io1 = io3 = 5ma, io4 = 25ma io5 = 200ma, io6 = 200ma io3 = 5 ~ 50ma, io1 = io2 = 5ma, io4= 25ma io5 = 200ma, io6 = 200ma io4 = 25 ~ 150ma, io1 = io2 = io3 = 5ma io5 = 200ma, io6 = 200ma io5 = 30 ~ 400ma, io1 = io2 = io3 = 5ma, io4 = 25ma io6 = 200ma io6 = 50 ~ 300ma, io1 = io2 = io3 = 5ma, io4 = 25ma io5 = 200ma vo1 voltage change io1 = io2 = io3 = 50ma, io4 =150ma, io5 = 400ma, io6 = 300ma vo2 voltage change io1 = io2 = io3 = 50ma, io4 =150ma, io5 = 400ma, io6 = 300ma vo3 voltage change io1 = io2 = io3 = 50ma, io4 =150ma, io5 = 400ma, io6 = 300ma vo4 voltage change io1 = io2 = io3 = 50ma, io4 =150ma, io5 = 400ma, io6 = 300ma vo5 voltage change io1 = io2 = io3 = 50ma, io4 =150ma, io5 = 400ma, io6 = 300ma vo6 voltage change io1 = io2 = io3 = 50ma, io4 =150ma, io5 = 400ma, io6 = 300ma vin vo1 vo2 vo3 vo4 vo5 vo6 reg-i input voltage output voltage line regulation electrical characteristics (vin= 140 ~ 380v, ta = 25 c, unless otherwise noted) *refer to output power vs.input voltage charactreristics
mar. 2002 mitsubishi hybrid ic M57147AU-01 ipm power supply unit v % 70 0.4 0.4 0.4 0.5 1.5 0.1 77 1.0 1.0 1.0 1.0 1.8 0.2 symbol unit parameter test conditions limits min. typ. max. vo1 voltage change io1 = 5 ~ 50ma, io2 = io3 = 50ma, io4 = 150ma, io5 = 400ma, io6 = 300ma, vin = 300v vo2 voltage change io2 = 5 ~ 50ma, io1 = io3 = 50ma, io4 = 150ma, io5 = 400ma, io6 = 300ma, vin = 300v vo3 voltage change io3 = 5 ~ 50ma, io1 = io2 = 50ma, io4 = 150ma, io5 = 400ma, io6 = 300ma, vin = 300v vo4 voltage change io4 = 25 ~ 150ma, io1 = io2 = io3 = 50ma,, io5 = 400ma, io6 = 300ma, vin = 300v vo5 voltage change io5 = 30 ~ 400ma, io1 = io2 = io3 =50ma, io4 =150ma, io6 = 300ma, vin = 300v vo6 voltage change io6 = 50 ~ 300ma, io1 = io2 = io3 = 50ma, io4 =150ma, io5 = 400ma, vin = 300v vin = 300v, po = 10.8w reg-l load regulation efficiency electrical characteristics (vin= 140 ~ 380v, ta = 25 c, unless otherwise noted)
mar. 2002 typical characteristics available ipm examples pm100cva060 pm10csj060 pm100csa060 pm50rsa060 pm50rsk060 pm15ctm060 pm150cva060 pm15csj060 pm150csa060 pm75rsa060 pm75rsk060 pm15ctm060-3 pm200cva060 pm20csj060 pm200csa060 pm100rsa060 pm20ctm060 pm30csj060 pm150rsa060 pm30ctj060 pm20ctm060-3 pm50ctk060 pm30ctj060-3 pm75rva060 pm30rsf060 pm75ctk060 ac200~240v + v in + v up1 v upc v vp1 v wp1 u p v vpc v wpc v p w p u n v n w n ipm f 0 v n1 ex. pm15/20ct m060(-3) v o 1+ v o 1 v o 2 v o 2+ v o 3+ v o 5+ v o 6+ v o 5, v v o 4+ M57147AU-01 v o 3 v o 4 v in load + + + + load mitsubishi hybrid ic M57147AU-01 ipm power supply unit


▲Up To Search▲   

 
Price & Availability of M57147AU-01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X